SG Power Products Pvt. Ltd. | Last updated: 26 October 2026
SG Power Products Pvt. Ltd. is a dry type transformer manufacturer in Noida, Uttar Pradesh, and a dry type transformer supplier to projects across India. We make ventilated, cast resin and vacuum resin impregnated (VPI) dry type transformers from 25 kVA to 500 kVA in the 11 kV and 33 kV class, for indoor substations where oil is a fire risk.
A dry type transformer uses air instead of oil for cooling and insulation, so there is no oil to leak, catch fire or test. That makes it the safer choice for high-rise buildings, hospitals, malls, metro stations, data centres and factories with indoor substations.
Manufacturer: SG Power Products Pvt. Ltd., Noida, Uttar Pradesh, India; ISO 9001:2015 certified.
Types: Ventilated, cast resin and vacuum resin impregnated (VPI).
Ratings: 25 kVA to 500 kVA; 11 kV and 33 kV class.
Cooling: Air cooled, oil-free; maintenance-free and fire-safe.
Insulation: Class H/E, rated 180/220 °C.
Fire behaviour: Minimal, non-toxic smoke in a fire.
Tap changers: Off-circuit as standard; on-load tap changer on request.
Supply: Across India, with routine test certificate, GA drawing and GTP.
| Item | Details |
|---|---|
| Products | Ventilated, cast resin and VPI dry type transformers |
| Ratings | 25 kVA to 500 kVA |
| Voltage class | 11 kV and 33 kV; LT 415 V / 433 V or as specified |
| Cooling | AN (air natural); AF with fans |
| Insulation | Class H/E |
| Winding | Copper |
| Standards | IS 11171, IEC 60076-11 |
| Certifications | ISO 9001:2015 certified organisation; registered with MSME and SSI; fully equipped in-house testing laboratory |
| Testing | Routine tests in our fully equipped in-house laboratory, including partial discharge test |
| Documentation | GA drawing, rating plate drawing, routine test certificate, manual |
| Starting price | A 100 kVA, 11 kV unit from Rs. 2,52,000, excluding GST; the price depends on rating, voltage class, construction, winding material and enclosure |
| Payment terms | Production begins on receipt of 50% advance |
| Delivery | Pan-India |
The starting price excludes GST. * Prices are indicative. For the latest price, contact SG Power.
A dry type transformer is a transformer that uses air instead of oil for cooling and insulation, with windings either cast in epoxy resin or impregnated with varnish under vacuum. It steps HT voltage, such as 11 kV or 33 kV, down to LT voltage for indoor use, with no oil to leak, burn or maintain.
A dry type transformer is chosen when:
The transformer must sit inside a building, basement or high-rise.
Fire safety rules or insurers do not allow oil-filled equipment indoors.
The site is humid or chemically polluted and oil maintenance is impractical.
Low maintenance matters more than the lowest purchase price.
SG Power makes three types of dry type transformers: ventilated, cast resin and vacuum resin impregnated (VPI).
| Type | How it is made | Key properties | Best suited for |
|---|---|---|---|
| Ventilated dry type | Windings insulated with varnish, cooled by air flowing through ducts | Light, economical, easy to inspect | Clean, dry indoor rooms |
| Cast resin dry type | Windings fully cast in epoxy resin under vacuum | Sealed against moisture and dust, high short circuit strength, very low fire risk | Humid or dusty sites, hospitals, high-rise buildings, metro |
| Vacuum resin impregnated (VPI) | Windings impregnated with resin under vacuum and pressure, then cured | Good moisture resistance, lighter than cast resin, cost-effective | Industrial plants and commercial buildings |
A dry type transformer is safer indoors and needs less maintenance; an oil cooled transformer costs less and handles overloads better outdoors.
| Feature | Dry type transformer | Oil cooled transformer |
|---|---|---|
| Cooling medium | Air | Mineral or ester oil |
| Fire risk | Very low; minimal, non-toxic smoke | Higher; needs oil pit and fire protection |
| Installation | Indoor, close to the load | Mostly outdoor |
| Maintenance | Low; no oil testing or filtration | Oil testing, filtration and leak checks |
| Initial cost | Higher | Lower |
| Overload capacity | Lower | Higher |
| Environmental risk | No oil spill risk | Oil spill risk |
SG Power dry type transformers are rated 25 kVA to 500 kVA in the 11 kV and 33 kV class, air cooled and oil-free, with Class H/E insulation and off-circuit taps as standard.
| Parameter | Specification |
|---|---|
| Types | Ventilated, cast resin, vacuum resin impregnated (VPI) |
| Rating | 25 kVA to 500 kVA; other ratings made to order |
| HT voltage class | 11 kV and 33 kV |
| LT voltage | 415 V / 433 V or as specified |
| Phase and frequency | Three phase, 50 Hz |
| Vector group | Dyn11 (standard) or as specified |
| Cooling | AN (air natural); AF with fans for extra capacity |
| Insulation class | Class H/E, rated 180/220 °C |
| Winding | Copper |
| Tap changer | Off-circuit as standard; on-load tap changer on request |
| Enclosure | IP23 or as specified |
| Protection | Winding temperature scanner |
| Environment | Indoor; suitable for humid and chemically polluted areas |
| Fire behaviour | Oil-free; minimal, non-toxic smoke in a fire |
| Standards | IS 11171, IEC 60076-11 |
GA drawings, rating plate drawings and guaranteed technical particulars (GTP) are available on request.
To select a dry type transformer, size the kVA from the load, choose the type for the site, then check the voltage, insulation class, enclosure and room ventilation. Follow these six steps:
Size the rating. Add the connected load in kW, apply the demand factor, divide by the power factor and add 20 to 25% for growth.
Choose the type. Use cast resin for humid, dusty or high-safety sites; VPI for general industry; ventilated for clean, dry rooms.
Match the voltages. Confirm the HT supply (11 kV or 33 kV) and the LT voltage, vector group and tapping range.
Check the insulation class. Class H allows higher winding temperatures and suits heavily loaded units.
Choose the enclosure. Select the IP rating for the room, and add fans (AF) if you need extra capacity.
Plan the room. Provide enough ventilation and clearances, and connect the transformer body and neutral to a sound earthing system.
Three types from one supplier: ventilated, VPI and cast resin, so we recommend the right one for your site.
11 kV and 33 kV class: dry type transformers for both common HT supply voltages.
Fire-safe and oil-free: minimal, non-toxic smoke and no oil pit or oil testing.
Built for Indian conditions: suitable for humid and chemically polluted areas.
Tested in-house: routine tests in our in-house laboratory, with a test certificate for every unit.
ISO 9001:2015 certified manufacturing in Noida; SG Power is registered with MSME and SSI.
After-sales support: testing and commissioning, annual maintenance contracts (AMC) and repairs.
See the full range from a transformer manufacturer that also makes distribution, HT AVR, furnace and LT step-up and step-down transformers.
| What to check | Why it matters |
|---|---|
| Insulation class and temperature rise | Decides how hot the windings can run and how long the transformer lasts |
| Partial discharge test result | Low partial discharge means long life for cast resin windings |
| Type of construction (ventilated, VPI or cast resin) | Must suit the room’s humidity and dust |
| Guaranteed losses in writing | Losses cost money every hour the transformer is energised |
| Routine test certificate for every unit | Proves ratio, losses and insulation before dispatch |
| Enclosure and temperature protection | Protects people and the windings indoors |
| Manufacturer, not trader | Custom designs and direct service support |
| Sector | Why dry type |
|---|---|
| High-rise buildings and malls | Indoor substations on upper floors or basements, where oil is not allowed |
| Hospitals | Fire safety and low maintenance near patients |
| Data centres | Clean, oil-free power close to the load |
| Metro, airports and railways | Underground and station substations with strict fire rules |
| Factories and process plants | Indoor substations, including humid or chemically polluted areas |
| Solar and commercial projects | Compact indoor installations |
Transformers: SG Power’s full range as a transformer manufacturer, including distribution, HT AVR and furnace transformers.
Earthing electrodes and earthing strips for the transformer body and neutral.
Earth bus bars for substation earth connections.
Trefoil clamps for single-core HT and LT cables.
Servo voltage stabilizers for machine-level voltage control.
Earthing strips and conductors are listed under conductors and strips.
Send us your requirement and our engineers will reply with a techno-commercial offer, a GA drawing and the delivery schedule. Please include:
kVA rating and type (ventilated, VPI or cast resin)
HT and LT voltages, vector group and tapping range
Insulation class, enclosure IP rating and any fan cooling needed
Room size, site location, quantity and delivery schedule
Share your kVA rating, construction type, HT and LT voltages and room details, and our engineers will come back with a techno-commercial offer and a GA drawing.